You can configure the Danalock V3 manually via the button found in the small hole on the top of the lock. See click commands available for your Danalock V3 further down this page.
When you get to the setting you want to change, wait for 5 seconds and the Danalock will react to your command. If you make a wrong number of clicks, just stop at a number of clicks where the LED doesn’t light up and wait for 5 seconds. The LED will flash red to indicate that it has timed out.
Clicks | Color | Activity |
1 | Green | Inclusion mode |
This mode is used to in- or exclude your Danalock with a Z-Wave or Zigbee gateway. When the Danalock blinks green it is in ex/inclusion mode and you have 30 seconds to pair the Danalock with a gateway. | ||
2 | Yellow | Manual calibration |
Start by turning the Danalock to the desired unlocked position. Start the calibration with the click command and wait for the LED to start blinking yellow. Turn the Danalock to the desired locked position while the LED blinks and click the button once to save the locked position. If the lock doesn’t receive a response from you within 30 sec the calibration will be canceled. |
||
3 | White | Auto calibration |
Start by turning the Danalock to unlocked position and lifting the handle if needed. The door has to be left open while the Danalock auto calibrates. Start the auto calibration with the click command. The Danalock will blink white while auto calibrating. | ||
10 | Red | Reset user settings |
This action deletes all user settings on the Danalock. The Danalock responds by blinking red. |
Clicks | Color | Activity |
2 | Yellow | Manual calibration |
Start by turning the Danalock to the desired unlocked position. Start the calibration with the click command and wait for the LED to start blinking yellow. Turn the Danalock to the desired locked position while the LED blinks and click the button once to save the locked position. The Danalock will confirm with a green blink. If the lock doesn’t receive a response from you within 30 sec the calibration will be canceled. |
||
3 | White | Auto calibration |
Start by turning the Danalock to unlocked position and lifting the handle if needed. The door has to be left open while the Danalock auto calibrates. Start the auto calibration with the click command. The Danalock will blink white while auto calibrating. | ||
4 | Blue | Hold Back Latch |
Toggles between 3 hold back latch settings: Off, short wait and long wait. Everytime this command is entered the setting will switch to the next option. • Off will respond with a red blink when being set, and will disable hold back latch. • Short wait will respond with short green blinks when being set, and will hold the latch back for 5 sec. • Long wait will respond with one long green blink when being set and will hold the latch back for 15 sec. |
||
5 | Purple | Auto Lock timer |
Toggles between 3 auto locking settings: Off, short wait and long wait. Everytime this command is entered the setting will switch to the next option. • Off will respond with a red blink when being set, and will disable auto locking. • Short wait will respond with short green blinks when being set, and will lock after 15 sec. • Long wait will respond with one long green blink when being set and will lock after 60 sec. |
||
6 | Cyan | End to End unlock |
Everytime this command is entered the setting will switch to the next option. • Turning off will respond with one red blink when being set. • Turning on will respond with one green blink when being set. |
||
8 | Blue/Green blink | Twist Assist |
Everytime this command is entered the setting will switch to the next option. • Turning off will respond with one red blink when being set. • Turning on will respond with one green blink when being set. |
||
10 | Red | Reset user settings |
This action deletes all user settings on the Danalock. The Danalock responds by blinking red. |